Omicron CT Analyzer - Precision Testing for Current Transformers
The Omicron CT Analyzer is a state-of-the-art diagnostic tool designed for comprehensive evaluation of current transformers (CTs) in substations and industrial power systems. It uses fully automated, low-voltage secondary injection testing, providing safe and efficient analysis without the need for high-current primary injections.
Features & Benefits
- Highly accurate measurements with up to 0.02% precision
- Safe testing up to 120 V using low-voltage secondary injection
- Determines key CT parameters: ratio, phase error, excitation curve, knee point
- Assesses burden impedance and winding resistance for detailed diagnostics
- Automatic pass/fail evaluation of CT class according to IEC and IEEE standards
- Measures saturation behavior, remanence, and transient parameters (TPX/TPY/TPZ)
- Lightweight design under 8 kg with rapid automated test sequences taking less than 1 minute
- Ideal for commissioning, maintenance, calibration, and performance diagnostics.
Material & Build
Built for reliability and portability, the Omicron CT Analyzer features robust construction optimized for field use. Its compact and lightweight design supports ergonomic handling, while advanced electronics ensure precise measurements and durability in demanding environments.
Use Cases / Applications
This instrument is perfect for substation engineers and industrial power system technicians who require fast, accurate and safe testing of current transformers. Use it during commissioning phases, routine maintenance, CT calibration, and for detailed insulation and performance analysis to ensure equipment compliance and operational safety.
Omicron CT Analyzer
DATASHEET
SPECIFICATIONS
1. Key Performance & Electrical
-
Application Focus: Automated on-site testing, calibration, and performance evaluation of protection and metering current transformers (CTs) according to IEEE and IEC standards
-
Generator Output: Variable output up to 120 V DC / AC (maximum 5 Aeff continuous, 15 Apeak) and up to 400 VAeff max power output for excitation and injection testing
-
Ratio & Phase Accuracy: Ultra-high measurement precision featuring a typical ratio error of 0.02% (0.05% guaranteed) and phase displacement accuracy of 1 min (typical) / 3 min (guaranteed)
-
Winding Resistance Measurement: Range covering secondary and primary circuits with a resolution of 1 mΩ and typical accuracy of 0.05%
-
Excitation Characteristics: Automatically determines knee point (up to 40 kV equivalent voltage via modeling), saturation curves, and magnetizing current behavior
-
Evaluated Parameters: Comprehensive measurement of composite error, accuracy limit factor (ALF/ALFi), instrument security factor (FS/FSi), burden impedance, and transient CT parameters (TPS, TPX, TPY, TPZ)
2. General & Physical
-
System Architecture: Compact, lightweight field unit designed for single-person transport and operation without requiring heavy primary injection equipment
-
Power Supply: Wide-range input power supporting 100 to 240 VAC, 50/60 Hz (permissible range 85 to 264 VAC, max input power 500 VA)
-
Software Integration: Controlled via PC running the CT Analyzer Suite software via USB/serial interface for automated test report generation and instant "pass/fail" assessment
-
Dimensions (W x H x D): Approx. 360 × 285 × 145 mm
-
Weight: Approx. 8 kg excluding standard cable accessories
-
Operating Temperature Range: -10 °C to +50 °C at 5% to 95% non-condensing humidity
-
RENTAL DETAILS & LOGISTICS
Rental Terms 1 Day minimum
Extension Terms Flexible Weekly / Monthly Extensions Delivery Nationwide & International Support 24x7 on-call + on-site support Availability UAE, Bahrain, Saudi Arabia, Spain RENTAL INQUIRIES & CONTACT
For rental inquiries, contact Skysun Energy via email at support@skysunenergy.com or by phone depending on the country you require.
-
Bahrain: +973 3312 1984
-
Saudi Arabia: +966 509674576
-
UAE: +971 5257 97530
-